  • 1(1714448383520).jpg
  • 消弧线圈成套(2).jpg

Arc suppression coil complete set

With the increasing scale of the power system, especially the extensive use of cables in the distribution network, the capacitive current of the system increases greatly. In this case, when a single-phase ground fault occurs, the arc formed by the grounding capacitive current at the fault point cannot be extinguished by itself.

Classification:

Key words:

Arc suppression coil complete set

Description

With the increasing scale of the power system, especially the extensive use of cables in the distribution network, the capacitive current of the system increases greatly. In this case, when a single-phase ground fault occurs, the arc formed by the grounding capacitive current at the fault point cannot be extinguished by itself. At this time, if the neutral point is grounded by the arc suppression coil, this problem will be solved well. Therefore, the power industry standard DL/T620-1997 "Overvoltage Protection and Insulation Coordination for AC Electrical Installations" clearly stipulates that when the single-phase grounding fault current is greater than 10A for the system composed of 3-10kV overhead lines and all 35,66kV power grids, the neutral point shall be equipped with an arc suppression coil; For the system composed of 3-10kV cable lines, when the single-phase grounding fault current is greater than 30A, the neutral point shall be equipped with an arc suppression coil.

On the basis of summarizing the operation experience of arc suppression coil control device for many years, our company has widely adopted the suggestions of new and old users, and successfully developed ZXHK series arc suppression coil automatic tuning and grounding line selection controller. The controller integrates automatic tuning and single-phase grounding line selection, which can not only measure and display the voltage and current signals of the neutral point in real time, but also calculate the capacitive current and detuning degree of the power grid accordingly, and realize automatic tracking tuning: the residual current, loop capacitance, neutral point voltage, current and other parameters of the current power grid are displayed in real time on the LCD screen of the controller panel; the current gear signal and fault alarm signal of the arc suppression coil have remote output, which can be connected to the dispatching center; moreover, it can adopt various criteria for single-phase grounding line selection. The controller is also equipped with a manual adjustment function for use when necessary.

Scope of application

ZXHK arc suppression coil automatic adjustment and grounding line selection device can be widely used in 6-66kV voltage level power system substations at all levels, large and medium-sized city distribution network and power plants, steel, coal, chemical, petroleum and other power systems. It is used to compensate the capacitive current of the power grid and improve the reliability and safety of the system power supply.

Online
Message


If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. Our staff will contact you in a timely manner, or please call us directly.